Light-SheetMicroscopy
In 2014, scientists built a microscope that could image everything from the minute dynamics of single molecules to the cellular trajectories of an entire, growing embryo. The lattice light-sheet microscope, developed by Eric Betzig’s group, uses thin sheets of patterned light to scan high-resolution, sub-cellular structure across cells and tissues in their native environment, in seconds.
It can record everything from transcription factors binding DNA, immune cells migrating and reshaping themselves in 3D, or chromosomes segregating over days of an embryo’s development. With this single instrument, it is possible to study objects spanning four orders of magnitude in time and space. [1]
In microscopy, there has historically been a tradeoff between speed and spatial resolution.
A microscope that can capture many images per second to observe fast dynamics across cells often suffers in spatial resolution.


For example, wide-field fluorescence microscopy can capture individual neurons firing, but tells you nothing about the organization of the intracellular compartments that produced that action potential.
On the other hand, a microscope imaging at high spatial resolution to see molecules or sub-cellular elements must compromise on time.
Electron microscopy can resolve the structure of individual ion channels that partake in action potentials, but requires that those molecules first be frozen in time; the photos are static. [2]
The animations of life, from the microsecond movements of individual molecules to the weeks-long process of cell differentiation and organism development, span more than 10 orders of magnitude in time and space. It’s this layering of emergent dynamics across scales, from the stochasticity of individual molecules to the near-deterministic behavior of whole organisms, that gives biological life its complexity.
Light-sheet microscopes are one of the most advanced ways to capture these dynamics across space and time, but they have yet to make their way into routine biology labs. That’s because the same functionality that makes them powerful also makes them complex and difficult to understand. A single state-of-the-art light-sheet microscope can cost upwards of a million dollars and requires nanometer-precision optical design and alignment. The device also images billions of pixels a second, across days, generating petabyte-scale data that needs vast computing resources and computational expertise. [3]
Making the
Light-Sheet
Microscope
In the traditional microscope configuration, the same objective lens illuminates the sample and collects the emitted light. But what if we had two objective lenses arranged perpendicular to each other, one for illumination and the other for collecting the emitted light?
Now, their elongated focal volumes intersect at right angles, and the intersection region is a smaller, more spherical volume from which fluorescence is detected.
This is what Ernst Stelzer’s lab was working on at the European Molecular Biology Laboratory. A paper published in 1994 showed a new type of microscope, the confocal theta microscope, that obtained a near-spherical region from which fluorescence was detected by placing two objectives at 90 degrees.
Is there a way to speed up volume acquisition that doesn’t require point-by-point scanning?
While this did not solve the speed problem (the spherical focal point still needed to be scanned in three dimensions to build an image of the sample), it set the stage for Stelzer’s lab to develop the light-sheet microscope.
A typical convex lens curves in two dimensions, bending the light rays also in two dimensions to form a cone that converges at a single point.
A cylindrical lens, however, curves only in one dimension, so the light also gets bent only in one dimension to produce a wedge of light that narrows toward a line rather than a point.
Near the focal line, the wedge narrows into a thin sheet of light that can be used to illuminate an entire plane of the sample at once.
By combining the perpendicular arrangement of objectives from confocal theta microscopy with a cylindrical lens for illumination, it becomes possible to illuminate an entire plane of the sample from one side while collecting the emitted fluorescence using a conventional microscope objective positioned at 90 degrees to the illumination direction.
The sheet of light formed by the cylindrical lens corresponds to the focal plane of the detection objective.
This is exactly what Jan Huisken and his colleagues were developing in Ernst Stelzer’s lab in the 2000s.
With this system, Huisken studied embryogenesis in GFP-tagged Medaka fish and in the more opaque fruit fly Drosophila. Over the next few years, light-sheet microscopy was used to track a zebrafish from a single fertilized egg to more than 20,000 cells over its first 24 hours, following the fate of every cell. [5]
Huisken’s group later combined optogenetics with light-sheet imaging to watch the heart’s pacemaker live and simulate abnormal cardiac events during development. [6]
But studying individual cells or small groups of cells is not enough to understand how they function together to form tissues and organs. As we move into thicker biological samples, like whole tissues or even small organisms, light gets scattered and distorted as it passes through the tissue, degrading the image resolution.
Several other techniques can be combined with light-sheet microscopy to push a microscope system to resolve even finer details or increase the speed of acquisition. For example, adaptive optics, a technique originally developed for astronomy, measures and corrects distortions in the light as it travels through different parts of the tissue, allowing us to image deeper into biological samples. Structured illumination is another technique that combines sequences of images acquired with different illumination patterns with computational techniques to extract finer spatial details within the tissue. Smart microscopy uses real-time image analysis to dynamically adjust which parts of the sample get imaged and how. [9] Each advance after Huisken’s original light-sheet microscope overcame a different limitation, technical or biological: the Bessel beam created a uniformly thin sheet of light to overcome the diverging beam of the cylindrical lens; lattice light-sheet improved upon the Bessel beam to increase contrast by reducing out-of-focus light; adaptive optics corrects for aberrations introduced into the light wavefront by biological tissues.
Together, these advances have made it possible to observe biological processes across a large range of spatial and temporal scales, from the movement of individual molecules inside cells to the coordinated activity of entire tissues and organs. Scientists can now watch immune cells migrating through large tissues, observe how mechanical forces propagate through three-dimensional tissues, or efficiently capture rare cellular events using real-time feedback. [10] But despite these advances, the most powerful light-sheet microscopes remain largely confined to specialized laboratories.
Bottlenecks
to Scaling
Light-Sheet
Microscopy
Each technical advance means more instrument engineering that requires specialized expertise. While the original light-sheet microscope can be built for a few tens of thousands of dollars by an enterprising graduate student, a lattice light-sheet microscope with structured illumination and adaptive optics could run close to a million dollars and needs a highly trained optical engineer to build and maintain. Many efforts have been tried to make the systems more accessible to the broader biological community, but with limited success. [11]
Moreover, light-sheet microscopy redefined what big data meant in biological imaging. A single embryogenesis experiment that uses light-sheet microscopy can generate over 100 terabytes of data in 24 hours. That’s over a gigabyte per second of data. The classic set up—a personal computer sitting next to the microscope—does not work anymore. At these acquisition rates, a single experiment can produce more data than an ordinary computer can store, requiring dedicated infrastructure to transfer, store, and process it.
And even after the images have been processed into three-dimensional volumes, there is the much harder problem of extracting meaningful biological information from them. Whether it’s following thousands of cells over time, identifying rare biological events, or even extracting how structures change over time requires computational expertise that many biology labs do not have. The result is a gap between what the microscopes can capture and what scientists can meaningfully analyze.
In addition to expertise and data, there’s also a throughput bottleneck. You can’t visualize thousands of different molecule types moving through cells and tissues at once. Fluorescent tags typically limit you to follow one or two or three molecules at a time, and each tag has to be engineered and tested, which can take months, before you can even start collecting enough data to capture that molecule’s range of variability.
Investing in cutting-edge instrumentation, data infrastructure, and expert staff would cost millions of dollars to just get started, resources typically not available to any individual biology lab.
Even with the resources, the question remains, what discoveries would all this data enable?
One approach is a platform-style effort called the Cell Observatory launched by Eric Betzig and Gokul Upadhyayula at the University of California, Berkeley. The Advanced Bioimaging Center [12] at Berkeley is equipped with several microscopes called the MOSAIC. These microscopes [13] combine not only lattice-light sheet, structured illumination, and adaptive optics, but also super-resolution and two-photon microscopy. By imaging the same biological sample across scales, from individual molecules to cells, tissues, and whole organisms, the researchers aim to connect processes that are usually studied separately.
Instead of trying to piece together measurements from different samples or instruments, where differences in sample history or experimental conditions can make direct comparisons challenging, the goal is to build an integrated picture of how molecular and cellular interactions give rise to the behavior of an organism. Ultimately, the Cell Observatory aims to use these datasets to train a foundation model capable of interpreting biological dynamics across five or more dimensions: three in space, one in time, and at least one molecular marker.
The microscope, however, is only one part of the larger initiative, and perhaps the part that’s most complete. The team is also developing dozens of fluorescent reagents for molecular targets of interest, building a multi-million dollar compute facility that can handle petabytes of data daily with real-time processing, and, crucially, building a 5D vision transformer that can segment cells, identify cell types, and learn biological rules across space and time. The platform is built to handle multiple model organisms, including zebrafish, mouse embryos, and even human organoids.
Biology is not static.
Molecules are constantly moving, cells are dividing and responding to other cells, and organs are performing specialized functions. For most of the history of microscopy, improving our ability to see smaller structures meant sacrificing our ability to watch them move. While light-sheet microscopy does not eliminate this tradeoff completely, it has dramatically expanded the spatiotemporal range of biological processes we can observe in an organism in its natural environment. The challenge now is to put these capabilities into the hands of more biologists.
Smrithi Sunil is a biomedical scientist and science writer. Her research has focused on developing microscopy techniques to study the brain. She holds a PhD in Biomedical Engineering from Boston University.